Pressure switches

a proven technology for power plants

RDY

  • Differential pressure switch
  • Approval: ATEX EEx ia
  • Adjustable setpoint(s) and deadband
  • Measuring range: -2.5...2.5 mbar to 2.5...30 bar
  • Overpressure / Static pressure: 0.15 to 220 bar

Technical Data RDY4, RDY8

Technical Data RDY5

RDPN

  • Differential pressure switch
  • Adjustable setpoint(s) and deadband
  • Measuring range: -2.5...2.5 mbar to 2.5...30 bar
  • Overpressure / Static pressure: 0.15 to 220 bar

Technical Data RDHN

Technical Data RDPN

RPPE

  • Pressure switch for low and high pressure
  • Approval: ATEX EEx d
  • Adjustable setpoint(s) and deadband
  • Measuring range: -50...0 mbar to 60...600 bar
  • Overpressure / Static pressure: max. 800 bar

Technical Data - RPPE3, RPPE7

Technical Data - RPPE4

RPPY

  • Pressure switch for low and high pressure
  • Approval: ATEX EEx ia
  • Adjustable setpoint(s) and deadband
  • Measuring range: -50...0 mbar to 60...600 bar
  • Overpressure / Static pressure: max. 800 bar

Technical Data - RPPY3, RPPY7

RPPN

  • Pressure switch for low and high pressure
  • Adjustable setpoint(s) and deadband
  • Measuring range: -50...0 mbar to 60...600 bar
  • Overpressure / Static pressure: max. 800 bar

RP2E

  • Pressure switch with ATEX EEx d approval
  • Good resistance to vibrations and overpressure
  • Measuringe range: 0...1 to 0...100 bar
  • Overpressure / Static pressure: max 200 bar

RP2Y

  • Pressure switch with ATEX EEx ia approval
  • Good resistance to vibrations and overpressure
  • Measuringe range: 0...1 to 0...100 bar
  • Overpressure / Static pressure: max 200 bar

RP2N

  • Standard pressure switch
  • Good resistance to vibration and overpressure
  • Measuring range: 0...1 to 0...100 bar
  • Overpressure / Static pressure: max. 200 bar

RDE

  • Differential pressure switch
  • Approval: ATEX EEx d
  • Adjustable setpoint(s) and deadband
  • Measuring range: -2.5...2.5 mbar to 2.5...30 bar
  • Overpressure / Static pressure: 0.15 to 220 bar

Technical Data RDE4, RDE8

Technical Data RDE5

CPX

  • „Two threshold outputs (PNP transistors)
  • Compact and light-weight design
  • Measuring range: -1...0 to 0…600 bar

(Y)TED

  • Pressure switch
  • „Two threshold outputs (PNP transistors or galvanic isolation)
  • Intrinsically safe version
  • Robust stainless steel housing for severe industrial environments

(Y)TED hygienic

  • Hygienic pressure switch
  • „Two threshold outputs (PNP transistors or galvanic isolation)
  • Flush membrane with hygienic approval (3-A)
  • Robust stainless steel housing for severe industrial environments

CombiPress™ PFMN

  • Pressure transmitter / switch
  • Industrial
  • Flush diaphragm
  • CombiView DFON display
  • Programmable and auto-zero adjustable

CombiPress™ PFMH

  • Pressure transmitter / switch
  • Hygienic
  • Flush diaphragm, 3-A and EHEDG certified
  • CombiView DFON display
  • CIP / SIP-able
  • Programmable and 0-adjustment